audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

List of available display groups > < Measured values
Reading measured values
Reading measured values
–  With ignition switched off, connect vehicle diagnostic tester to diagnostic connection using diagnostic cable → Chapter.
–  Select vehicle system „02 - Gearbox electronics“. The ignition must be switched on.
   
Tester display (example):
–  From menu -1-, select diagnostic function „Measured values“ and advance by pressing button.
  A01-10024
Tester display (example):
–  Use keypad -2- to enter required „display group number“ → Chapter and confirm entry by touching Q button.
  A01-10026
Tester display (example):
1 - Display zones 1 ... 4. If a display zone is vacant, there is no display on this line.
2 - The selected display group is indicated in this field.
3 - Touch these buttons to switch to other display groups.
4 - Touch these buttons to change to a different function (e.g. from „Read measured value block“ to „Basic setting“ and vice versa).
–  Exit from diagnostic function „Measured values“ by touching button.
  A01-0176

List of available display groups > < Measured values