Checking combination valve for secondary air system for proper operation and leakage
Checking combination valve for secondary air system for proper operation and leakage
   
Test sequence
–  Take off engine cover panel -arrows-.
  A10-0885
–  Detach pressure hose -arrow- at secondary air pump.
  A26-0310
–  Blow lightly into pipe with your mouth (do not use compressed air).
l  The combination valve -arrow- should be closed; it should not be possible to blow through the valve.
–  Blow into pipe with your mouth using more pressure (do not use compressed air).
l  The combination valve for secondary air should open; it should now be possible to blow through the hose.
If combination valve for secondary air does not open:
–  Renew secondary air combination valve → Chapter.
  A26-0728