audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Testing signal wire between engine control unit and gearbox control unit > < Checking radiator fan after-run control unit -J138
Diesel Direct Injection and Glow Plug System (TDI 4 cyl.) >07.99
Checking auxiliary signals
Testing intake manifold flap changeover valve
  • ‒ Remove connector from changeover valve => installation positions overview, Page 23-7
  • ‒ Connect multimeter to valve to measure the resistance.
  • Specified value: 30...40 ω

If specified value is not attained:

  • ‒ Replace the changeover valve.
 
A23-0037

If specified value is attained:

  • ‒ → Connect the handheld multimeter (voltage range) between earth and contact 1 on the connector.
  • ‒ Switch the ignition on.
  • Specified value: approx. battery voltage

If specified value is not attained:

  • ‒ Connect test box V.A.G 1598/22 to wiring harness for engine control unit =>Page 23-39.
 
A23-0037

The following wiring connections are to be checked for open circuits and/or short to positive or negative.

2-pin connector on wiring harness, contact

Test box V.A.G 1598/22, socket

1

2

1

28

2

3

  • ‒ Rectify any open/short circuit as necessary.

Testing signal wire between engine control unit and gearbox control unit > < Checking radiator fan after-run control unit -J138