audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking secondary air inlet valve -N112 > < Checking exhaust gas recirculation system
Motronic injection and ignition system (4-cyl.)
Checking exhaust gas recirculation system
Adaption of exhaust gas recirculation valve
 
W00-0706

Special tools and workshop equipment required

  • ◆ VAS 5051 with VAS 5051/1
  • or
  • ◆ V.A.G 1551 with V.A.G 1551/3 A

Test sequence

  • ‒ Connect vehicle diagnostic, testing and information system VAS 5051 or fault reader V.A.G 1551 and select engine electronics control unit with "address word" 01 .
    Ignition must be on.
 
→ Display readout:
Rapid data transfer     HELP
Select function XX
  • ‒ Enter "04" for "Start basic setting" function and confirm with Q key.
 
→ Display readout:
Basic setting    Q
Enter display group number XXX
  • ‒ Enter "074" for "Display group number 074" and confirm with Q key.
  • ‒ Check specification for exhaust gas recirculation valve in display zone 4.

Display zones

1

2

3

4

Display group 074: Adaption of exhaust gas recirculation valve

Display

x.x V

x.x V

xxx %

---

Readout

Zero position

Max. stop

Duty cycle

Adaption status

Operating range

0...100 %

ADP in progress
ADP OK
ADP ERROR

Specification

0...2 V

3.0...5 V

0...100 %

ADP OK

Note

If reading does not match specification, check exhaust gas recirculation valve for dirt and foreign matter

If reading does not match specification: Check exhaust gas recirculation valve
=> 4-cyl. Engine (5-valve), Mechanics; Repair Group 26

Note on display zone 4:

The abbreviation "ADP" in display zone 4 stands for "Adaption".

Checking secondary air inlet valve -N112 > < Checking exhaust gas recirculation system