A3 Mk1
Testing ignition system
Testing intake air temperature sender -G42
|
Special tools and workshop equipment required
Fitting location => Fitting locations overview, Page 24-5 Test sequence
|
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
|||||||||||||||||||||||||||||||||||
1) Possible readouts: When the vehicle is being driven this figure may be up to 24 °C higher than ambient temperature. When the vehicle is standing, temperatures up to 120 °C are possible due to heat radiated from the engine. Checking wiring connections
|
If no wiring fault is detected: Testing sender |
Specifications:
Example: If the air temperature is between 0 °C and 20 °C, the resistance should be between 5.5 kωand 2.4 kω. If the specification is not attained:
|