Cleaning throttle valve module > < Performing adaption of throttle valve module
Checking for contamination of throttle valve
Checking for contamination of throttle valve
  Note
t  Ensure that the correct type of air cleaner is fitted (genuine part) and that it is in proper condition.
t  Intake air duct OK
t  Fuel pressure OK
t  Fuel tank breather function OK
t  Injectors OK
t  Coolant temperature > 80 °C
Lambda probe learnt values and Lambda control function OK
Cleaning throttle valve → Chapter
Checking Lambda probe learnt values and Lambda control function
–  Connect vehicle diagnosis and service information system -VAS 5052- to engine control unit. Engine must be idling.
–  Select “Basic setting”.
   
Display on tester:
1 - Enter display group (highest possible entry = 255)
–  Use the keypad -2- to enter “032” for “Display group number 032” and confirm by touching the Q key.
  A01-0130
Display on tester:
–  Check the specification in display zone -2-.
  A01-0139
 Display zones
 1234
Display group 032: Lambda learnt values
Displayxx.x %xx.x %  
DisplayLambda learnt value
bank 1, probe 1
at idle (additive)
Lambda learnt value
bank 1, probe 1
at part load
(multiplicative)
  
Specification-9.0...9.0 %-25.0...25.0 %  

Procedure
–  Unplug the connector from the air mass meter.
–  Connect up the vehicle diagnosis and service information system -VAS 5052- and select vehicle system “Engine electronics”. Engine must be idling.
–  Select Basic setting.
  Note
   
Display on tester:
1 - Enter display group
–  Enter “107” for “Display group number 107” and confirm by touching the Q key.
  A01-0130
Display on tester:
–  Check the display in zone -4-.
  A01-0163
 Display zones
 1234
Display group 107: Lambda control, short trip
Displayxxx rpmx.x %x.x %Test ON
DisplayActual engine speedLambda control
mean value (bank 1)
Lambda control
mean value (bank 2)
Diagnosis status
Operating range   Test OFF
Test ON
Syst. OK
Syst. n.OK
Specification   Syst. OK

If the reading matches the specification “Syst. OK” in display zone 4:
–  Touch the ▾ key.
–  Re-connect the air mass meter.
–  For further fault-finding, perform the next step in the fault table.
If “Syst. n.OK” is displayed in zone 4:
–  Touch the ▾ key.
–  Use a lint-free cloth and cleaning fluid to clean the air duct in the throttle valve module.
–  Perform throttle valve module adaption again → Chapter
–  Repeat test sequence: Lambda control, short trip; Measured value block 107 in Basic setting 04
–  Re-connect the air mass meter.
–  Erase the fault memory → Chapter.
–  Perform a test drive. Heed the safety instructions → Chapter
–  Fault memory interrogated → Chapter
   