Audi Workshop Service and Repair Manuals
HOME
FEATURES
MENU
INDEX
ABOUT US
Checking fuel tank breather >
< Checking actuation of secondary air pump relay
A3 Mk1
Power unit
Simos injection and ignition system (4-cylinder)
Mixture preparation system, electronic inj.,Gas
Checking secondary air pump relay J299 and actuation
Checking voltage supply for secondary air pump motor
Checking voltage supply for secondary air pump motor
Checking voltage supply for secondary air pump motor
–
Remove centre noise insulation
-arrows-
.
–
Unplug connector from secondary air pump motor -V101-.
–
Connect voltage tester -V.A.G 1527 B-between contacts 1 and 2.
–
Initiate final control diagnosis and actuate the secondary air pump relay -J299-.
t
The LED should flash.
If the LED does not flash:
–
Perform the following checks marked with a dot.
l
Check for open circuit in wiring of contact 1 of connector and earthing point on the left in the engine compartment:
→ Current flow diagrams, Electrical fault finding and Fitting locations
l
Check for open circuit in wiring from contact 2 of connector for secondary air pump relay -J299- (in relay carrier under left cover at bulkhead):
→ Current flow diagrams, Electrical fault finding and Fitting locations
If no fault is found:
–
Replace the secondary air pump motor -V101-.
Power unit
Simos injection and ignition system (4-cylinder)
Mixture preparation system, electronic inj.,Gas
Checking secondary air pump relay J299 and actuation
Checking voltage supply for secondary air pump motor
Checking fuel tank breather >
< Checking actuation of secondary air pump relay