audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking auxiliary signals > < Testing modulating piston movement sender and quantity adjuster
TDI Injection and Glow Plug System (4-cyl.) 08.99 >
Checking control unit input values
Testing intake manifold flap changeover valve
  • ‒ Removing connector from changeover valve => fitting locations overview, Page 23-4
  • ‒ Connect multimeter to valve to measure the resistance.
  • Specified value: 30...40 ω

If specified value is not attained:

  • ‒ Replace the changeover valve.
 
A23-0037

If specified value is attained:

  • ‒ → Connect the hand-held multimeter (voltage range) between earth and contact 1 on the connector.
  • ‒ Switch the ignition on.
  • Specified value: approx. battery voltage

If specified value is not attained:

  • ‒ Connect test box V.A.G 1598/31 to wiring harness for engine control unit; do not connect the engine control unit .
 
A23-0037

The following wiring connections are to be checked for open circuits and/or short to positive or negative.

2-pin connector on wiring harness, contact

Test box V.A.G 1598/31, socket

1

1. 2

2

81

  • ‒ Rectify any open/short circuit as necessary.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Checking auxiliary signals > < Testing modulating piston movement sender and quantity adjuster