audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing exhaust gas recirculation valveN18 with exhaust gas recirculation potentiometerG212 > < Exhaust gas recirculation system - exploded view
Checking adaption of zero position for exhaust gas recirculation valveN18
Checking adaption of zero position for exhaust gas recirculation valve -N18-
  Note
t  After renewing the engine control unit or the exhaust gas recirculation valve -N18-, the control unit and the valve must be adapted to one another → Rep. gr.24.
t  Check the adaption status and the zero position before performing repair measures.
t  On vehicles complying with emissions standard EU2 (PR No. „0GV“) it is not possible to adapt the exhaust gas recirculation valve -N18- since this function is not active in the control unit software. The PR No. „0GV“ is listed on the vehicle data sticker.
Special tools and workshop equipment required
   
t  Vehicle diagnostic, testing and information system -VAS 5051B- with diagnosis lead -VAS 5051/5A-
  W00-10343
Test sequence
–  Connect up vehicle diagnostic, testing and information system -VAS 5051B- with diagnosis lead -VAS 5051/5A- and select vehicle system „01 - Engine electronics“ from list. Engine must be idling.
–  From list -1- select diagnostic function „04 - Basic setting“.
  A01-0122
–  Enter „074“ for „display group number 074“ in zone -2- and confirm the entry by pressing the Q key.
1 - Enter display group
  A01-0130
–  Activate basic setting by touching key A.
–  Check display in display zones -1- and -4-.
  A01-0163
Display group 002
Display zonesExplanatory notes
1 Zero position of exhaust gas recirculation valve -N18-
… V
l  Specification: 0.3 ... 1.2 V
If specification is not obtained:
–  Check exhaust gas recirculation valve for dirt and foreign particles. If necessary, renew exhaust gas recirculation valve.
4 Adaption status of exhaust gas recirculation valve -N18-
l  ADP runs
l  ADP. O.K.
l  ERROR
If specified value „ADP. O.K.“ is not obtained:
–  Perform electrical test of exhaust gas recirculation valve -N18- in „Guided Fault Finding“ → Vehicle diagnostic, testing and information system VAS 5051.

  Note
The abbreviation „ADP“ in display zone 4 stands for „Adaption“.
–  Exit function „04 - Basic setting“ by pressing the  key.
–  Press „06 - End output“.
–  Switch off ignition.
   

Removing and installing exhaust gas recirculation valveN18 with exhaust gas recirculation potentiometerG212 > < Exhaust gas recirculation system - exploded view