audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Wiring to fresh air blower control unit J126 > < Temperature-sensitive resistances of temperature sensors/senders
Test step “3”
Test step “3”
Power supply and wiring to fresh air blower control unit -J126- and fresh air blower -V2-
t  Test step 3.1 Checking power supply to fresh air blower -V2-
–  Switch off ignition.
–  Remove glove box. → General body repairs, interior; Rep. Gr.68
   
–  Unplug connector -A- from fresh air blower control unit -J126--B-.
–  Measure voltage between contact -4- and contact -3- at connector -A-.
Specification: approx. battery voltage
  Note
t  If the voltage is below battery voltage, use current flow diagram to repair power supply/earth connection.
t  On vehicles with “sun roof with solar cells” as optional extra, the voltage generated by the sun roof solar cells is applied to contact -6- of the connector -A- when the sun roof is closed.
t  The fresh air blower control unit -J126- is constantly monitored by the operating and display unit, Climatronic control unit -J255-. Any faults occurring are stored in the fault memory. The current status of the fresh air blower -V2- is displayed in the measured value block (display group “018”) → Chapter.
  A87-0388

Wiring to fresh air blower control unit J126 > < Temperature-sensitive resistances of temperature sensors/senders