Checking the function of the positioning motor for the fresh-air/recirculated-air flap -V154 and the switch -E159 > < Removing and installing the fresh-air blower -V2
Heating, Air Conditioner
Repairing heating - vehicles from Model Year 1997
Removing and installing positioning motor for fresh-air/recirculated-air flap -V154

Removing

  • ‒ Remove the glove box

=> General Body Assembly, Interior; Repair group 68; Storage compartments/covers; Removing and installing glove box

 
A80-0072
  • ‒ → Detach connector -A-.
  • ‒ Remove bolt -B-.
  • ‒ Remove positioning motor -C- in the direction of the arrow.

Installing

Installation is carried out in the reverse order; note the following:

  • ‒ When inserting the positioning motor, ensure that the bracket -D- is correctly positioned in slot -E-.
  • ‒ Install the positioning motor.
  • ‒ If the lever is positioned so unfavourably that the motor cannot be installed, inserted connector -A-.
  • ‒ Switch the ignition on.
 
A80-0073
  • ‒ → Now actuate the fresh-air/recirculated-air flap until the lever -F- on the positioning motor is in the centre position.