Simos injection and ignition system (4-cylinder)
Reading measured value block (data block)
Reading measured value block (data block)

Requirements for test:

  • ● Coolant temperature at least 80 °C
  • ● Electrical consumers switched off (radiator fan must not run during the test)
  • ● Air conditioner switched off

Test sequence

  • ‒ Connect vehicle diagnostic, testing and information system VAS 5051 (or fault reader V.A.G 1551) and select engine electronics control unit by entering address word "01" ( .)
    When doing this the engine must be idling.
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Enter "08" to select the function "Read measured value block" and confirm entry with Q key.
 
→ Indicated on display:
Read measured value block    Q
Enter display group number XXX
  • ‒ Enter the required Display Group number (3 figures) and confirm entry with Q key.

Note:

The choice of display group number depends on which functions and components are to be tested.

 
→ Indicated on display for Display Group 000:
Read measured value block    0    ⇒
    1    2    3    4    5    6    7    8    9    10

 
→ Indicated on display (example) for Display Group 001:
Read measured value block    1    ⇒
1    2    3    4

Notes:

  • ◆ If the printer is switched on, the current display can be printed out.
  • ◆ Other display groups can be selected as follows:

Display group

V.A.G 1551

VAS 5051

Higher

Press key 3

Press skey

Lower

Press key 1

Press tkey