audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing selector lever lock solenoid N110 > < Exploded view - selector mechanism
Removing and installing selector mechanism
Removing and installing selector mechanism
Special tools and workshop equipment required
   
t  Socket and key -T40031-
Removing
–  Remove selector lever handle → Chapter.
–  Remove air conditioner operating unit → Rep. Gr.87.
–  Remove ashtray in centre console → Rep. Gr.68.
  W00-1181
–  Release the 4 retainers -arrows- and lift off the cover -1- including the guide.
–  Unplug electrical connector from the side of the guide.
–  Unplug electrical connector at selector lever lock solenoid -N110-.
  A37-0458
–  Lift retaining tab -A- and pull off locking cable laterally in direction of -arrow-.
  A37-10401
–  Shift selector lever to position “D”.
–  Insert socket and key -T40031- through access hole in selector mechanism and loosen clamping bolt at rear of selector lever cable approx. 1 turn.
  Note
t  Only loosen clamping bolt approx. one turn - do not remove.
t  Clamping bolt can only be accessed with selector lever in position “D”.
t  With clamping bolt loosened, selector lever must remain in position “D”.
  A37-10831
–  Remove rear noise insulation (loosen fasteners -2- and -3-).
  A10-1320
–  Remove front tunnel brace -2-, to do so unscrew bolts -1-.
  Note
-Items 3 and 4- can be disregarded.
  A66-10043
  Caution
The flexible joint (de-coupling element) on the front exhaust pipe must not be bent more than 10° – otherwise it can be damaged.
–  Unscrew nuts -arrows- from connections in front of and behind particulate filter.
–  Tie up particulate filter to body (electrical wiring and pressure lines remain connected).
  A26-10126
–  Remove heat shield below selector mechanism -arrows-.
  A37-10832
Vehicles with noise insulation -A- located below selector mechanism:
–  Remove the four retaining washers -arrows-.
–  Pull off noise insulation -A- and slide it forwards on selector lever cable.
  A37-10403
All models:
–  Pull off retaining clip -1- for selector lever cable from the side.
–  Pull selector lever cable -2- out of selector mechanism.
  Note
Do not bend or kink the selector lever cable.
  A37-10402
–  Remove nuts -arrows-.
  Note
The assistance of a second mechanic is required to detach the selector mechanism from below.
–  Press retaining clips -1- and -2- inwards, while pushing selector mechanism downwards.
Installing
l  Tightening torque → Fig.
Installation is carried out in reverse sequence; note the following:
  Note
Renew retaining washers.
–  Install selector lever cable → Chapter.
–  Adjust selector lever cable → Chapter.
–  Install locking cable → Chapter.
–  Adjust locking cable → Chapter.
–  Install particulate filter → Rep. Gr.26.
–  Install heat shield below selector mechanism → Rep. Gr.66.
–  Check selector mechanism → Chapter.
  A37-0460

Removing and installing selector lever lock solenoid N110 > < Exploded view - selector mechanism