A4 Quattro Cabriolet V6-3.2L (BKH) (2007)
Exhaust Pipe: Service and Repair
Right Front Exhaust Pipe With Catalytic Converter (Vehicles With A/T 09L), Removing and
Installing
Right Front Exhaust Pipe With Catalytic Converter (vehicles With Automatic Transmission 09L), Removing And Installing
Removing
NOTE: All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.
-
Remove rear engine cover - arrows - .
-
Disconnect check valve - 1 - from connection at air duct hose.
-
Remove air duct hose, thereby loosening hose clamp - 2 - and opening clips - arrows -.
-
Disconnect electrical harness connector - 2 - for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130 and free up wiring.
NOTE: Ignore - 1 - .