Remove the air duct hose, thereby loosening the hose clamp - 2 - and opening the clips - arrows -.
-
Disconnect the electrical harness connector - 2 - for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and free up the
wiring.
‹› Ignore - item 1 -.
-
Remove nut - 2 - which is accessible from top for front exhaust pipe/exhaust manifold.