The ATF level is correct when ATF drips out only lightly from the outlet before 45 °C is reached.

‹› Approximately 5 cl of ATF will initially drain from the internal oil level pipe. This is normal.

-

If no additional ATF flows out, rotate the shut off valve back in the direction of the filler hose and fill with more ATF; repeat the check of the ATF
level.

-

After reaching the correct ATF level, remove the shut off valve again.

‹› After removing the shut off valve, the ATF drips out lightly.

-

Replace and tighten the ATF inspection plug.

‹› Tightening specification: 24 Nm.

‹› At the latest at 45 °C (50 °C for hot countries) the ATF inspection plug - B - must be installed again.

‹› At an ATF temperature above 45 °C, too much ATF flows out due to heat build up and the transmission is not filled sufficiently!

-

Press <- button to end function "08 - Read measured value block".