Measuring radial clearance of crankshaft |
Special tools and workshop equipment required |
Note t
| Mark used bearing shells for re-installation (but do not mark bearing surface). |
t
| Bearing shells worn down to the base layer must be renewed. |
–
| Remove retaining frame and clean bearing journals. |
–
| Place a length of Plastigage corresponding to the width of the bearing on the bearing journal or in the bearing shell. |
l
| The Plastigage must be positioned in the centre of the bearing shell. |
–
| Fit retaining frame and tighten to 30 Nm. Do not rotate crankshaft. |
–
| Remove retaining frame again. |
–
| Compare width of Plastigage with measurement scale. |
l
| New: 0.015 ... 0.055 mm. |
|
|
|