Rear Vision Camera: Adjustments

Rear View Camera System, Calibrating 

After performing service work on the vehicle, it may be necessary to calibrate the rear view camera system anew. In detail, this is the case after: 

-

Removing and installing Rear View Camera R189 

-

Replacing Rear View Camera System Control Module J772 

-

after repair work performed on rear lid following an accident 

-

after a vehicle alignment 

-

after performing a repair at front or rear axle 

Preparations before starting work

Special tools, testers and auxiliary items required 

-

Vehicle Diagnostic, Testing and Information System VAS 5051 

-

Calibration Device VAS 6350 

-

Distance Laser VAS 6350/2 

Vehicle must stand on a firm and level surface to perform the calibration. No persons may be in the vehicle interior during the measurement.
Vehicle must not be moved during the measurement, opening and closing of vehicle doors is to be avoided. The rear lid is closed. 

-

Connect. 

-

Bring the Steering Angle Sensor G85 into 0-position (wheels straight ahead). 

Overview of assembled measuring device, sedan

1. Left paddle 
2. Right paddle 
3. Right-side angle bracket for Distance Laser VAS 6350/2 mount. 
4. Plastic foot 

-

Three on underside of calibration platform 

-

Adjustable for aligning horizontal position of calibration platform 

5. Linear laser on calibration platform 

-

Switching on and off Operating instructions 