A8 Sedan V8-3.7L (AEW) (1997)
Maintenance Required Lamp/Indicator: Service and Repair
Channel 07 (Inspection 1 Service Interval Value - Time/Days)
SRI, inspection indicator (In 1), resetting (time)
Initiate Adaption Function.
-
Press button -0- and -7- to select channel 7.
-
Press -Q- button to confirm input.
Channel 7 Adaptation 36 ->
<-13->
-
Advance through program sequence with button ->.
Channel 7 Adaptation 36 Q
Input adaptation value XXXXX
-
Enter adaptation value between 0 days (00000) and 360 days (00036). The value can be entered in steps of 10 days. Example: 360 days ,therefore
enter 00036.
-
Press -Q- button to confirm input.
Channel 7 Adaptation 36 Q
<-13->
-
Press -Q- button to confirm input.
Channel 7 Adaptation 36 Q
Store changed value?
-
Press -Q- button to confirm input.
Channel 7 Adaptation 36 ->
Changed value is stored
-
Press -> button to end coding.
Rapid data transfer HELP
Select function XX
-
Press buttons -1- and -0- to select "Adaptation" function 10.
Rapid data transfer Q
10 - Adaptation
-
Press -Q- button to confirm input.
Adaptation
Insert channel number XX