Trip Computer: Technical Service Bulletins
Fuel Range, Coolant Temperature, CIS-E Signal, RPM and Fuel Mileage Sender Checks

Fuel range display sender, checking

Note

If fuel tank contents are not the same as displayed quantity, display can be adjusted with screw in side of instrument cluster

-

disconnect 35-point connector from instrument cluster (not illustrated)

FUEL RANGE DISPLAY SENDER

-

connect US 1119 between contact 24 and ground

-

measure resistance

^

380.0 ohm - tank empty

^

40.0 ohm - tank full

If specified values are not obtained, - repair break in wiring according to wiring diagram OR
-

replace defective fuel range display sender

If specified values are still not obtained, - replace instrument cluster

Coolant temperature display sender, checking

COOLANT TEMPERATURE DISPLAY SENDER

-

disconnect 35-point connector from instrument cluster

-

connect US 1119 between contact 26 and ground

-

measure resistance when eng. temp.                resistance

is approx.:

is approx.:

20~C (  68~F)

1000 ohm

40~C (104~F)

500 ohm

60~C (140~F)

180-200 ohm

90~C (194~F)

75-100 ohm

110~C (230~F)

45-60 ohm

120~C (248~F)

35-45 ohm