‹› Position - H - shows the respective adjustment range of the control motors.

‹› If both control motor levers are not located in the position depicted, the control motor(s) may be connected via a 5A fuse to a 12 V battery e.g.

using an adapter lead => [ Connecting Adapter Cable to Activate Control Motors ] See: Service and Repair/Procedures/Connecting Adapter Cable
to Activate Control Motors (or an adapter lead from connector test kit (V.A.G 1594/C) to terminals " 5" and "6"). Rotate control motor for only as
long until it has reached the position depicted (the turning direction can be reversed by swapping Plus and Minus).

-

Check position of threaded plates - J -.

‹› Bolts - G - are used as a guide when installing retaining plate, if they are screwed in too far, the retaining plate cannot be installed, if they are not

screwed in far enough, it may possibly cause noise.

-

Connect connectors to the control motors (note assignment, risk of interchange) and secure wiring harness to retaining plate.

-

Insert retaining plate on to bolts - F -, when doing this make sure that studs on levers of control motors - A - to -  C - are guided into lever guides
on flaps - D - to -  F -.

-

Slide retaining plate - B - with control motors on to heating & A/C unit from below.

-

Check routing of electrical wire and make sure while installing that the wires do not come into contact with moving parts of the control motors and
flap levers.

-

Check position of bolts - C - and their fit in retaining plate guides (if retaining plate fits too loosely on bolts - C -, screw them in if necessary far
enough that there is no longer any play--do not tighten).

-

Install bolts - A -.

-

Install retaining plate - C - with control motors (V108) and (V158) => [ Retaining Plate with Left Footwell Flap Motor and Left Temperature Flap
Motor ] See: Retaining Plate with Left Footwell Flap Motor and Left Temperature Flap Motor (only present on "Comfort" version A/C system).