audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Rearview Camera System Overview, Through October 31, 2008|Page 7041 > < Rearview Camera System Overview, Through October 31, 2008|Page 7039
Page 6
background image

-

Note the value read off.

-

Repeat measuring procedure in the same manner for the rear wheel on the other side of the calibration platform.

The distance value must be the same on both sides.

If values are not identical:

-

Adjust calibration platform until values on both sides are identical. 

When aligning the calibration platform, make sure the laser beam still strikes the center of the Audi rings and the indicator in the spirit level remains
centered. If necessary, make further corrections.

-

Measure height of calibration platform, dimension - H - (top edge platform - floor).

The measured distance and height must now be entered in the Diagnostic Operation System (VAS 5051A) in " millimeters".

Performing calibration

In Diagnostic Operation System (VAS 5051A), select "Guided Functions".

or

In Diagnostic Operation System (VAS 5051A), select "Guided Fault Finding".

-

Select the corresponding vehicle data in the "vehicle selection " menu.

-

Select "rear view camera system".