Disconnect electrical connector - 1 - on Mass Air Flow (MAF) Sensor (G70).

-

Disconnect the vacuum line - 3 - from the air guide pipe.

CAUTION!
Risk of violating emissions legislation.

‹› Do not open hose connection - 2 -!

-

Lay aside air guide pipe with connected crankcase ventilation hose - 2 - by loosening hose clamp - 4 - and opening clips - arrows -.

Continuation for the right secondary air injection (AIR) combi-valve:

-

Remove secondary air hose - arrow - by pressing the release buttons.

‹› Ignore - 1, 2 and 3 -.

Continued for both sides:

-

Connect the auxiliary hose - arrow - to the combination valve for Secondary Air Injection (AIR).