If the engine shows problems in certain temperature ranges and if the temperature does not climb uniformly, the temperature signal is intermittent
and the sensor should be replaced.

-

End diagnosis and switch ignition off.

If indications do not resemble description:
 
Checking internal resistance

-

Disconnect harness connector -4- at Engine Coolant Temperature (ECT) Sensor -G2-/-G62-.

NOTE:  Disregard the other items.

-

Connect multimeter between terminal C and D of sensor for resistance measurement.

Range A displays resistance values for the temperature range of 0...50 degree C, range B displays resistance values for the temperature range of 50...100
degree C
.  

Read-out examples: 

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohms

-

80 degree C corresponds to a resistance of 275 to 375 Ohms

If specified value is not obtained: 

-

Replace Engine Coolant Temperature (ECT) sensor (G62).

If specified value is obtained: