audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 5486 > < With Manufacturer's Scan Tool|Page 5484
Page 2
background image

-

Connect multimeter at valve for resistance measurement.
-

Specified value: 22 ... 30 Ohm

If specified value is not obtained.  

-

Replace Evaporative Emission (EVAP) canister purge regulator valve - N80-.

If specified value is obtained: 

Checking voltage supply

-

Connect multimeter between terminal 1 and 2 for voltage measurement.

-

Operate starter briefly.
-

Specified value: approx. battery voltage

If there is no voltage: 

-

Connect multimeter for voltage measurement as follows:

Harness connector

Measure to

Terminal 

1

Engine Ground (GND)

-

Operate starter briefly.
-

Specified value: approx. battery voltage

If there is no voltage again:   

-

Check wire connection from harness connector terminal 1 to Fuel Pump (FP) Relay -J17- via fuse for open circuit according to wiring diagram. 
-

Specified value: Wire resistance max 1.5 Ohm

-

If necessary, repair wire connection. 

If voltage supply is OK:

Check Ground (GND) activation

With Manufacturer's Scan Tool|Page 5486 > < With Manufacturer's Scan Tool|Page 5484