S6 V8-4.2L (BBD) (2004)
-
Connect hand-held multimeter to following socket on connector to measure voltage:
4-pin connector on
wiring harness, socket
Specified value
1 + Ground
Battery voltage
-
Operate starter.
Specified value: approx. battery voltage
If specified value is not attained:
-
Check wiring from socket 1 via fuse to fuel pump relay for continuity, repair, if necessary.
If the specified value is achieved:
-
Check performance output stage. See: Ignition Coils With Power Output Stage, Checking