TT L4-1.8L Turbo (BEA) (2004)
15
Central flap
-
Note installation position (shorter section of flap faces up).
16
Footwell/defroster flap
-
Lightly lubricate hinge pivots with grease G 052 745 A3 or equivalent.
17
Temperature flap
18
Seal
-
Refer Fig.2 given below
18
Threaded bracket
19
O-Ring
20
O-Ring
21
Expansion valve
22
Bolt
-
Tightening torque: 8 Nm (71 in lb).
23
Air deflector
Fig. 1 Air distribution housing, assembly
-
Secure both halves of the housing with screws -A- at locations (example) -B-.
Fig. 2 Refrigerant pipe seal at evaporator, installing
Evaporator refrigerant pipes -C- must be completely encapsulated by seal -A- between both halves of the air distribution housing -B-.
-
After securing both halves of the housing, apply silicone seal as necessary at any open locations. Housing must be completely sealed against entry
of hot air from the engine compartment or warm air from the passenger compartment, otherwise, cooling efficiency will be affected.
Fig. 3 Evaporator seal, installing