audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6678 > < Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6676
Page 2
background image

NOTE:  Do not bend or stretch lines or hoses as compressor and refrigerant lines/hoses may be damaged.

-

Remove bolts - arrows -.

-

Remove condenser from charge air cooler.

-

Remove condenser - A - downward.

Installing

-

Torque specification: Bolts for securing compressor (to charge air cooler) - 5 Nm

Installation is done is reverse order, observe the following:

NOTE:  The removed condenser contains refrigerant oil that must be returned to the refrigerant circuit (with the new condenser).

-

Ensure sealing strips - arrows - have adhered correctly to condenser - A -.

Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6678 > < Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6676