Secondary Air Injection (AIR) pump relay -1- (under cover, left at bulkhead) must trigger and the Secondary Air Injection (AIR) pump motor
-V101- must run in intervals. The relay -2- need not be observed in this context (it is involved supplying voltage for the Motronic ECM power
supply relay -J271-)

A -

If relay does not trigger:

-

Check voltage supply of the Secondary Air Injection (AIR) pump relay.

-

Check activation of the Secondary Air Injection (AIR) pump relay.

B -

If relay triggers, but Secondary Air Injection (AIR) pump does not run:

-

Check voltage supply of the Secondary Air Injection (AIR) pump motor.

Checking voltage supply of Secondary Air Injection (AIR) pump relay

-

Switch ignition off.

-

Remove Secondary Air Injection (AIR) pump relay -1-.

-

Connect multimeter for voltage measurement as follows (left relay carrier):

Relay carrier below left cover,

Measure to

at bulkhead