If no malfunctions are detected:

-

Replace Secondary Air Injection (AIR) pump relay -J299-.

Check voltage supply of the Secondary Air Injection (AIR) pump motor

-

Remove center noise insulation (arrows).

-

Disconnect connector for Secondary Air Injection (AIR) pump motor -1- (V101).

-

Connect VAG1527B voltage tester between terminals 1 and 2

-

Initiate output Diagnostic Test Mode (DTM) and activate Secondary Air Injection (AIR) pump relay -J299-. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's
Scan Tool
-

LED must blink.

If LED does not blink:

-

Perform the following tests marked with dots:
-

Check wire connection from connector at Secondary Air Injection (AIR) pump motor -V101- to Secondary Air Injection (AIR) pump relay
-J299- (in relay carrier below cover, left at bulkhead) for open circuit:

IMPORTANT:  Check wire connection from connector at Secondary Air Injection (AIR) pump motor -V101- to Ground (GND) point in engine
compartment, left, for open circuit:

If no malfunctions are detected:

-

Replace Secondary Air Injection (AIR) pump motor -V101-.