5 Series E39 M5 (S62) SAL
12 72 520
Removing and installing / replacing pedal
travel sensor (S62)
Switch off ignition.
Remove trims for instrument panel at bottom.
Installation:
Perform function check:
Connect DIS Tester.
Measure voltage (V) and percentage values (%) at PWG
potentiometer with DIS Tester.
Only the higher value from the two values specified is taken into
account here.
Specified values:
1.
Pedal travel sensor in idle position: 0.6 to 0.85V.
2.
Pedal travel sensor in full throttle position: 110 -130%.
Note:
If the idle measurement value is outside the above-mentioned limit
value, the 71
°
angle of the lever must be checked and a new lever
fitted in the event of correction.
Operate accelerator pedal for full throttle position by hand to
prevent a distortion of the measured values.
Readjust the full throttle stop on the accelerator pedal if the
percentage values in the full throttle position do not attain the
values mentioned above.
Location:
The pedal travel sensor (1) is fitted to the pedal block.
RA Removing and installing / replacing pedal travel sensor (S62)
BMW AG - TIS
21.02.2013 16:24
Issue status (12/2007) Valid only until next DVD is issued
Copyright