5 Series E39 M5 (S62) SAL
Note:
Because of the closing force of the return spring in the
servomotor, one or both dial gauge(s) can display a slight
deviation from zero (approx. 0.01 mm). Do not correct gauge
dials.
Connect servomotor to engine wiring harness.
Activate servomotor by means of DIS Tester or MoDiC to specified
value 1 %.
Caution!
Do not open throttles by hand.
Servomotor shaft with twin lever would thus receive a different
radial position. This would result in an incorrect measurement
result and incorrect throttle setting.
When the servomotor is activated at 1 %, throttles 3 and 6 are
opened to such an extent that the dial gauges indicate a change
between 0.2 mm and 0.4 mm. Check whether both dial gauges
indicate the same value.
If necessary, turn hexagon head (1) on adjustable pull rod
(cylinder bank 5-8) slightly until both dial gauges indicate the same
opening value for throttles 3 and 6.
Enter specified value of 0 % and re-enter specified value of 1 %.
Check whether both dial gauges indicate the same opening value
for throttles 3 and 6.
Deviation between both dial gauges must be less than 0.03 mm.
Adjusting full-load adaptation stop:
Activate servomotor until throttles are fully open and stop
screw (1) rests against stop lug.
RA Performing throttle basic setting (S62)
BMW AG - TIS
21.02.2013 16:34
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 12 -