Park Avenue V6-3.8L SC VIN 1 (2005)
1. Install the new O-ring to the evaporator hose.
2. Install the new expansion tube.
IMPORTANT: Ensure that the short screen and arrow face the evaporator.
3. Connect the evaporator hose.
Tighten the fitting to 24 N.m (18 lb ft).
NOTE: Refer to Fastener Notice in Service Precautions.
4. Position the evaporator hose to the accumulator cover and press to engage.
5. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
6. Leak test the fittings of the A/C component using the J 39400-A.