Rendezvous FWD V6-3.5L VIN L (2006)
5. Using the J 39194-B, remove the HO2S.
INSTALLATION PROCEDURE
IMPORTANT: A special anti-seize compound is used on the HO2S threads. The compound consists of liquid graphite and glass beads. The graphite
will burn away, but the glass beads will remain, making the sensor easier to remove. New or service sensors will have the compound applied to the
threads. If a sensor is removed and is to be reinstalled, the threads must have an anti-seize compound applied before reinstallation.
1. If reinstalling the old HO2S, coat the threads with anti-seize compound GM P/N 12377953 or equivalent.
2. Using the J 39194-B, install the HO2S.
NOTE: Refer to Fastener Notice.
Tighten the sensor to 41 N.m (30 lb ft).