buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Connecting Rods, Push Rods, Bell Cranks|Page 8367 > < Connecting Rods, Push Rods, Bell Cranks|Page 8365
Page 2
background image

Install or Connect

NOTICE:  Before installing new actuator (1), lock assembly (2) must be in full-open position (9) and teeth (13) on the lock switch (14) (part of the
actuator) must be pushed fully toward actuator arm (11) to prevent damage to lock switch when lock assembly is operated.

1. Release lock assembly (2) to be sure it is in the full open position (9). Do this by pushing up or outside lock rod lever (8) and pulling on inside

lock handle lever (4).

2. Before placing new actuator on lock assembly you must first position plastic teeth of loci switch. Push teeth (13) fully toward actuator arm (11) so

they will mesh correctly with teeth on lock assembly when installed.

3. Verify that actuating arm rubber bumper (10) is on actuating arm (11). Install actuating arm and bumper into locking lever (12), align lock switch

teeth to gear tooth forkbolt (15) and align screw holes.

4. Attach two Torx(R) screws.
5. Manually operate lock assembly by pushing inward on fork bolt until it clicks into fully closed position (as shown). Lock must operate to fully

closed position without any interference.

6. Connect electrical connections and test operation of actuator and lock switch.
7. Lock assembly.
8. Be sure lock carrier is properly mounted and retained.

Connecting Rods, Push Rods, Bell Cranks|Page 8367 > < Connecting Rods, Push Rods, Bell Cranks|Page 8365