CTS RWD V6-3.6L (2008)
Air Door Actuator / Motor: Service and Repair
Recirculation Actuator Replacement (RHD)
Recirculation Actuator Replacement (RHD)
Removal Procedure
1. Remove the air inlet assembly. Refer to Air Inlet Assembly Replacement (See: Air Duct/Service and Repair/Air Inlet Assembly Replacement) .
2. Disconnect the electrical connector from the recirculation actuator.
3. Remove the recirculation actuator screws (1).
4. Remove the recirculation actuator.
Installation Procedure
1. Install the recirculation actuator.
Notice: Refer to Fastener Notice .
2. Install the recirculation actuator screws (1).
Tighten the screws to 1 N.m (9 lb in).
3. Connect the electrical connector to the recirculation actuator.
4. Install the air intake assembly. Refer to Air Inlet Assembly Replacement (See: Air Duct/Service and Repair/Air Inlet Assembly Replacement) .