cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Fuel Line Quick Connect Fitting Connect/Disconnect Procedure|Page 3373 > < Fuel Line Quick Connect Fitting Connect/Disconnect Procedure|Page 3371
Page 2
background image

Fuel Line Connector - Type 1

TYPE 1 QUICK CONNECTOR

DISCONNECT:

1.

Flush the fuel pipe quick connector with water and using compressed air, blow out the debris from the connector.

2.

Remove the collar lock.

3.

Grasp the large collar of the connector, twist in either direction and pull the connector off the male pipe end.

CONNECT:

1.

Using a clean shop towel, wipe off the male pipe end.

2.

Apply a few drops of clean engine oil to the male pipe end.

3.

Before connecting the quick connectors, ensure that the large collar of the connector has rotated to its original position.  Examine the connector
inside diameter, the springs must be visible.

4.

Insert the connector onto the male pipe end pressing firmly together until the springs snap into place.

5.

Check that the connector is locked on by trying to pull the connector away from the male pipe end.

6.

Install the collar lock onto the connector.  Snap the legs of the collar over the flats on the connector body.

Fuel Line Connector - Type 2

TYPE 2 QUICK CONNECTOR

DISCONNECT: