Cobalt L4-2.4L VIN B (2006)
Air Door Actuator / Motor: Service and Repair
Recirculation Actuator
RECIRCULATION ACTUATOR REPLACEMENT
REMOVAL PROCEDURE
1. Remove the fuse labeled HVAC CTRL (BATT).
2. Remove the instrument panel (I/P) retainer.
3. Disconnect the recirculation actuator electrical connector.
4. Remove the recirculation actuator screw.
5. Remove the recirculation actuator.
INSTALLATION PROCEDURE