Equinox AWD V6-3.4L (2008)
1. Install the bolt to the drive belt tensioner .
Notice: Refer to Fastener Notice .
2. Install the drive belt tensioner and bolt as an assembly to the generator bracket.
Tighten the bolt to 50 N.m (37 lb ft).
3. Insure the drive belt is properly centered on all the pulleys except the right idler pulley (3).
4. Using J 39914 rotate the drive belt tensioner away from the drive belt.
5. Install the drive belt to the right idler pulley (2).
6. Carefully release J 39914 allowing the drive belt tensioner (8) to come in contact with the drive belt.
7. Remove J 39914 from the drive belt tensioner (8).
8. Inspect the drive belt to insure the belt is properly centered on all the pulleys (1-8).
9. Install the air cleaner intake duct. Refer to Air Cleaner Inlet Duct Replacement .
10. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .