8. Remove the suction line O-rings seals and discard.
INSTALLATION PROCEDURE
IMPORTANT: The new O-ring seals must be lubricated with mineral base 525 viscosity refrigerant oil.
1. Install the new O-ring seals onto the suction line.
2. Install the suction line into the block fitting.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the suction line block fitting bolt.
Tighten
Tighten the suction line block fitting bolt to 16 N.m (12 lb ft).
4. Install the suction line nut (1) at the accumulator.
Tighten
Tighten the suction line nut to 47 N.m (35 lb ft).