Installation Procedure

1. Install the air cleaner outlet duct.
2. Position and install the air cleaner outlet duct to the MAF/IAT sensor and the throttle body.
3. Position the air cleaner outlet duct insulator and spacer, if required.

Notice:  Refer to Fastener Notice.

4. Install the air cleaner outlet duct bolt (1).

Tighten the bolt to 10 N.m (89 lb in).

5. Tighten the air cleaner outlet duct clamps at the MAF/IAT sensor and throttle body.

Tighten the clamps to 4 N.m (35 lb in).