13. Ensure the distance between the end of the stoplamp switch plunger and the end of the threaded portion of the stoplamp switch is within 2.4 mm
(0.02-0.094 in).
14. Tighten the locknut (1) for the stoplamp switch.
^
Tighten the locknut to 10 Nm (89 in. lbs.).
15. Install the left side air outlet duct to the I/P. Secure the outlet duct with the screw.