chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Drive Motor Generator Control Module Sight Shield Replacement|Page 4689 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4687
Page 4
background image

1. Install new APM coolant seal (3).
2. Position the APM (2) onto the PIM ensuring the seals remain in place.

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution) .

3. Install the APM mounting fasteners (1). Tighten the mounting fasteners to 10 Nm (89 lb in ).

Note

Only use pre-mixed DEX-COOL(R) on the coolant pipe O-ring to aid in tube installation.

4. Lubricate the new seals (6, 9) with pre-mixed DEX-COOL(R).
5. Install new seals (6, 9) onto the drive motor generator power inverter coolant pipes (5, 8).
6. Install the coolant pipes (5, 8) to the PIM assembly with bolts (4, 7). Tighten the fasteners to 5 Nm (44 lb in) .

7. Rotate the drive motor generator control module assembly onto the APM.
8. Clamp GE-48494 - adapter kit components (2, 3) to a coolant pipe.
9. Plug the remaining coolant pipe with the GE-48494 - adapter kit plug and clamp (1).

Drive Motor Generator Control Module Sight Shield Replacement|Page 4689 > < Drive Motor Generator Control Module Sight Shield Replacement|Page 4687