Air Door Actuator / Motor: Description and Operation
HVAC System - Automatic

Air Temperature Actuator Description and Operation

AIR TEMPERATURE ACTUATOR

The air temperature actuators are a 5 wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference,
control, 5 volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 5 volt signal to command the
actuator movement.

When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5 volt control signal commands the actuator movement in opposite directions.
When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal between 0-5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The doer position signal voltage is converted to a 0-255 count
range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 5 volts depending upon the direction that the
actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the
position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

AUXILIARY AIR TEMPERATURE ACTUATOR-VIN 6

The auxiliary air temperature actuator is a 5 wire bi-directional electric motor that incorporates a feedback potentiometer. Low reference, 5 volt
reference, position signal, and two control circuits enable the actuator to operate. The control circuits use either a 0 or 12 volt value to coordinate the
actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the auxiliary HVAC
control module grounds one of the control circuits while providing the other with 12 volts. The control module reverses the polarity of the control
circuits to move the actuator in the opposite direction. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position
signal between 0-5 volts.

The auxiliary HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a
0-255 court range. When the module sets a commanded, or targeted, value, one of the control circuits is grounded. As the actuator shaft rotates the
changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module grounds both control
circuits.

HVAC Control Components

DEFROST ACTUATOR

The defrost actuator is a 5 wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 5
volt
 reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5 volt signal to command the
actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5 volt control signal commands the actuator movement in
opposite directions. When the actuator shaft rotates, the potentiometer's adjustable contact changes the coor position signal between 0-5 volts. The
HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count
range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 or 5 volts depending upon the direction that
the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the
position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

MODE ACTUATOR

The mode actuator is a 5 wire bi-directional electric motor that incorporates a feedback potentiometer. Ignition 3 voltage, low reference, control, 
5-volt reference and position signal circuits enable the actuator to operate. The control circuit uses either a 0, 2.5 or 5 volt signal to command the
actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5 volt control signal commands the actuator movement in
opposite directions. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal between 0-5 volts.

The HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a 0-255 count
range. When the module sets a commanded, or targeted, value, the control signal is changed to either 0 or 5 volts depending upon the direction that
the actuator needs to rotate to reach the commanded value. As the actuator shaft rotates the changing position signal is sent to the module. Once the
position signal and the commanded value are the same, the module changes the control signal to 2.5 volts.

AUXILIARY MODE ACTUATOR-VIN 6 

The auxiliary mode actuator is a 5 wire bi-directional electric motor that incorporates a feedback potentiometer. Low reference, 5 volt reference,
position signal, and two control circuits enable the actuator to operate. The control circuits use either a 0 or 12 volt value to coordinate the actuator
movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the auxiliary HVAC control
module grounds one of the control circuits while providing the other with 12 volts. The control module reverses the polarity of the control circuits to
move the actuator in the opposite direction. When the actuator shaft rotates, the potentiometer's adjustable contact changes the door position signal
between 0-5 volts.

The auxiliary HVAC control module uses a range of 0-255 counts to index the actuator position. The door position signal voltage is converted to a
0-255 count range. When the module sets a commanded, or targeted, value, one of the control circuits is grounded. As the actuator shaft rotates the
changing position signal is sent to the module. Once the position signal and the commanded value are the same, the module grounds both control
circuits.

HVAC System - Manual|Page 10645 > < HVAC System - Manual|Page 10643