Sebring Convertible V6-2.5L SOHC 24 Valve (1996)
6.
Measure 3-3/4 inches (95 mm) forward of the first bolt in the sill from the A-pillar. Now measure from the floor pan up 3/4 inch (20 mm) on the
cowl side sheet metal. Make a mark where the two points cross. Figure 2
7.
Remove foam sealant at location for drilling.
8.
Drill a 9/32 (7 mm) hole thru the cowl side sheet metal into the reinforcement tube.
9.
Coat the self tapping screw with RTV sealant (P/N 82300234).
10.
Install the 8 mm (P/N 06504772) self tapping screw and a 24 mm (1 inch) washer. Do not tap the hole before installing the screw.
NOTE:
ENSURE THAT THE SCREW AND WASHER ARE SQUARE TO THE SHEET METAL BEFORE TORQUING.
11.
Torque the screw to 24 Nm (210 in lbs.).
12.
Vacuum up all shavings from drilling procedure.
13.
Place sound deadner, wiring harness and carpet back into original position.
14.
Install cowl side panel trim.
15.
Install door sill trim panel.
16.
Repeat procedure for other side if needed.
POLICY: Reimbursable within the provisions of the warranty.
TIME ALLOWANCE:
Labor Operation No:
23-85-57-92
0.5 Hrs.
Right Side
23-85-57-93
0.5 Hrs.
Left Side
FAILURE CODE:
CX - Squeaks