9. Install new O-rings on the suction hose and the liquid evaporator pipe at the fire wall and put the pipes back in place.
10. Install the retaining nuts that secure the suction hose and the liquid evaporator pipe blocks at the fire wall.
Tighten
Tighten the suction hose and the liquid evaporator pipe retaining nuts to 10 N.m (89 lb-in).
11. Fill the cooling system.
12. Recharge the A/C system. Refer to Manual Control Heating, Ventilation, and Air Conditioning System.
13. Connect the negative battery cable.