dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Recirculation Door Actuator - Removal
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Door Actuator - Installation

INSTALLATION

NOTE: Illustrations shown with instrument panel removed for clarity.

NOTE: LHD model shown. RHD model similar.

1. Position the recirculation door actuator (1) to the right side of the HVAC air inlet housing (2).
2. Install the recirculation door actuator onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator output

shaft (3) with those on the recirculation door pivot shaft adapter (4).

3. Install the screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 Nm (17 in. lbs.).
4. Connect the instrument panel wire harness connector (4) to the recirculation door actuator.
5. Install the glove box binSee: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument Panel Glove Box -

Installation.

6. Reconnect the negative battery cable.

Air Door Cable, HVAC > < Recirculation Door Actuator - Removal