dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Removal and Replacement|Page 5893 > < Removal and Replacement|Page 5891
Page 7
background image

1. Install the four mode door levers (1, 2, 3 and 4) onto the right side of the air distribution housing (5) Make sure the lever retaining tabs are fully

engaged to the housing.

NOTE: Properly position the air doors within the air distribution housing by first aligning the four mode door levers to the scribe lines

located on the right outer side of the air distribution housing. Then, install the air doors onto the mode door levers with the UP mark
on each air door facing toward the top of the housing.

NOTE: If a seal on an air door is deformed or damaged, the air door must be replaced.

2. Align the four mode door levers to the scribe lines on the right outer side of the air distribution housing (5) and install the air door(s) (1, 2, 3 and

4) onto the mode door levers with the UP mark on each air door facing toward the top of the housing.

3. Align the air door(s) with the pivot shaft hole(s) in the air distribution housing (3) and install the two halves of the housing together. Make sure the

three plastic retaining tabs (6) are fully engaged.

4. Install the five screws (4) and one metal clip (5) that secure the two halves of the air distribution housing together. Tighten the screws to 2.2 Nm

Removal and Replacement|Page 5893 > < Removal and Replacement|Page 5891