Grand Caravan V6-3.3L Flex Fuel (2008)
NOTE: LHD model shown. RHD model similar.
1. Disconnect and isolate the negative battery cable.
2. If equipped, remove the silencer from underneath the passenger side of the instrument panel.
3. Remove the two screws (1) that secure the recirculation door actuator (3) to the driver side of the HVAC air inlet housing (4) and remove the
actuator from the housing.
4. Disengage the red locking tab and disconnect the wire harness connector (2) from the recirculation door actuator and remove the actuator from the
vehicle.
Recirculation Door Actuator - Installation
INSTALLATION
NOTE: LHD model shown. RHD model similar.
1. Position the recirculation door actuator (3) to the driver side of the HVAC air inlet housing (4) and connect the wire harness connector (2) to the
actuator and engage the red locking tab.
2. Install the recirculation door actuator onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator with the
recirculation door pivot shaft.
3. Install the two screws (1) that secure the recirculation door actuator to the air inlet housing. Tighten the screws to 1.2 Nm (10 in. lbs.).
4. If equipped, install the silencer underneath the passenger side of the instrument panel.
5. Reconnect the negative battery cable.
6. Calibrate the A/C-heater controlSee: Service and Repair/Procedures/HVAC Actuator Calibration Procedure.