dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Hose/Line HVAC|Service and Repair > < Plumbing|Page 1682
Page 1
background image

Hose/Line HVAC: Testing and Inspection

REFRIGERANT SYSTEM LEAKS

WARNING:  R-134A SERVICE EQUIPMENT OR VEHICLE A/C SYSTEM SHOULD NOT BE PRESSURE TESTED OR LEAK TESTED
WITH COMPRESSED AIR. MIXTURE OF AIR AND R-134A CAN BE COMBUSTIBLE AT ELEVATED PRESSURES. THESE
MIXTURES ARE POTENTIALLY DANGEROUS AND MAY RESULT IN FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.

AVOID BREATHING A/C REFRIGERANT AND LUBRICANT VAPOR OR MIST. EXPOSURE MAY IRRITATE EYES, NOSE AND
THROAT. USE ONLY APPROVED SERVICE EQUIPMENT MEETING SAE REQUIREMENTS TO DISCHARGE R-134A SYSTEM. IF
ACCIDENTAL SYSTEM DISCHARGE OCCURS, VENTILATE WORK AREA BEFORE RESUMING SERVICE.

If the A/C system is not cooling properly, determine if the refrigerant system is fully charged with R-134a. If while performing this test A/C liquid line
pressure is less than 345 kPa (50 psi) proceed to System Empty procedure. If liquid line pressure is greater than 345 kPa (50 psi) proceed to System
Low procedure. If the refrigerant system is empty or low in refrigerant charge, a leak at any line fitting or component seal is likely. A review of the
fittings, lines and components for oily residue is an indication of the leak location.

To detect a leak in the refrigerant system, perform one of the following procedures as indicated by the results of the refrigerant system charge level test.

SYSTEM EMPTY

1. Evacuate the refrigerant system to the lowest degree of vacuum possible (approx. 28 in Hg.). Determine if the system holds a vacuum for 15

minutes. If vacuum is held, a leak is probably not present. If system will not maintain vacuum level, proceed with this procedure.

2. Prepare a 0.284 Kg. (10 oz.) refrigerant charge to be injected into the system.
3. Connect and dispense 0.284 Kg. (10 oz.) of refrigerant into the evacuated refrigerant system.
4. Proceed to the SYSTEM LOW procedures.

SYSTEM LOW

1. Position the vehicle in a wind-free work area. This will aid in detecting small leaks.
2. Bring the refrigerant system up to operating temperature and pressure. This is done by allowing the engine to run for five minutes with the system

set to the following:
-

Transaxle in Park

-

Engine idling

-

Rear A/C Off (if equipped)

-

A/C controls set to 100 percent outside air

-

Blower switch in the highest speed position

-

A/C in the On position

-

Front windows open

CAUTION: A leak detector designed for R-12 refrigerant (only) will not detect leaks in a R-134a refrigerant system.

3. Shut off the vehicle and wait 2 to 7 minutes. Then use an electronic leak detector that is designed to detect R-134a type refrigerant and search for

leaks. Fittings, lines, or components that appear to be oily usually indicates a refrigerant leak. To inspect the evaporator core for leaks, insert the
leak detector probe into the drain tube opening or a heat duct. A R-134a dye is available to aid in leak detection, use only DaimlerChrysler
approved refrigerant dye.

Hose/Line HVAC|Service and Repair > < Plumbing|Page 1682